王毅刚,俞悟周,盛胜我.阻抗管中采用伪随机信号的三点测量技术[J].声学技术,1995,(4):158~161 |
阻抗管中采用伪随机信号的三点测量技术 |
Three-microphone-position method using pseudorandom signal in the impedance tube measurement |
投稿时间:1995-03-21 |
DOI: |
中文关键词: |
英文关键词: |
基金项目:国家自然科学基金资助 |
|
摘要点击次数: 1343 |
全文下载次数: 946 |
中文摘要: |
本文在分析双传声器──传递函数测量技术缺陷的基础上,提出了伪随机信号的三点测量技术。该技术很好地解决了双传声器──传递函数技术存在的两传声器间距不能为半波长整数倍的问题;采用伪随机信号解决了声场不一致问题以及采用单通道测量避免了双通道测量的不匹配问题。该技术在传统的驻波管中具有实际应用价值。 |
英文摘要: |
By analyzing disadvantages of the two-microphone transfer function technique,the three-microphone- position method using a pseudorandom signal is presented in this paper for measuring acoustic properties in the impedance tube. The problem due to the distance between the two microphones being not an integer multiple of the half-wavelength of sound in the two-microphone-transfer function technique can thus be solved in our new method. By using a pseudorandom signal as the noise source,the same sound field is set up for a broadband analysis and the mismatch of the amplitude or phase responses in two-channel measurement is avoided by using single channel only,This method is praticable in the traditional standing wave tube measurement. |